HO5V2-U, HO7V2-U

HO5V2-U 300/500 V HO7V2-U 450/750 V

H05V2-U harmonized cable provides rigid single-core copper conductors with high-temperature resistant PVC insulation, making it suitable for fixed indoor wiring in appliances and surface or embedded conduit installations. Its robust design ensures stable electrical performance, improved heat tolerance and safe operation in lighting and electrical circuits. Great choice for residential and commercial electrical wiring needs.

Cable Structure
Conductor : Solid copper conductor, class 1 DIN VDE 0281,IEC 60228
Insulation : Heat - resistant polyvinyl chloride (PVC) insulation
Color : Green/Yellow, Blue, Black, Brown, Grey, Orange, Pink, Red, Violet, White, Green, Yellow or other colours
Flame propagation : Flame retardant test as Per IEC 60332-1
Technical Data
Operating Temp : -20°C to max.+80°C
Nominal Voltage : HO5V2-U : 300/500 V | HO7V2-U : 450/750 V
Test Voltage : HO5V2-U : 2000V | HO7V2-U : 2500V
Insulation resistance : Min. 10 MΩ x km
Min. bending radius : 4 x Cable Diameter
Applications
 HO5V2-U, HO7V2-U
-   For internal wiring of appliances as well as installation in an electrical conduit pipe either on or underneath plaster
 Standard length cable packing:
-   Coils 100 and 200 m in Carton Boxes, Reels
Cable Features
Special heat resistant insulation
High Current Carrying Capacitys
Less heat energy radiation
Good application of insulation
Excellent resistant to moisture, abrasion, grace, oil
Excellent mechanical & electrical properties
harmonized acc. to European standards
Insulation is highly thermal stable
Tested by SGS, EIL, RITES, NPC, INTERTEK

HO5V2-U (300/500 V)

Size in
mm
Nos/ dia.
(Nom.)
Insulation Thickness
in mm ( nom.)
Outer Dia
in mm (Appx.)
Max. C.R in
ohm/km Copper
0.5 1/0.80 0.60 2.10 36.00
0.75 1/0.97 0.60 2.20 24.50
1 1/1.13 0.60 2.60 18.10
  All are class 2 stranded conductor
  Insulation grade is TI1

Note

The number of wires is approximate and wire diameter is nominal; they shall be such as to satisfy the requirements of conductor resistance of IEC 60228 / DIN VDE 0295 / IS 8130 / BS 6360

HO7V2-U (450/750 V)

Size in
mm²
Nos/ dia.
(Nom.)
Insulation Thickness
in mm ( nom.)
Outer Dia
in mm (Appx.)
Max. C.R in
ohm/km Copper
1.5 1/1.38 0.70 3.00 12.10
2.5 1/1.78 0.80 3.60 7.41
4 1/2.24 0.80 4.10 4.61
6 1/2.24 0.80 4.70 3.08
10 1/3.57 1.00 5.80 1.83
  All are class 2 stranded conductor
  Insulation grade is TI1