Heavy-duty EPDM rubber 3 & 4 core flat cables designed for submersible pump power supply with high flexibility and excellent resistance to oils, chemicals, ozone, and weathering. Equipped with flexible stranded copper conductors and rugged rubber insulation and sheath, these cables ensure dependable performance in submerged, wet, and harsh conditions. Ideal for deep well and agricultural pump installations.
For continuous use in deep well to supply power to submersible motors for the depth upto 500 mtrs.
| Conductor | Rubber Insulation | Rubber Sheath | Conductor Resistance at 20°C (Max) |
Current Rating at 40°C Amps. |
||||
|---|---|---|---|---|---|---|---|---|
| Nominal Size in |
Nos. & Dia of Wire |
Nominal Thickness |
Nominal Core Dia |
Nominal Thickness |
Approx. Overall Dimensions |
|||
| Sq. mm. | Nos./mm | mm | mm | mm | Height mm | Width mm | ||
| 1.50 | 22/0.30 | 0.80 | 3.25 | 1.15 | 6.20 | 12.80 | 12.10 | 23 |
| 2.50 | 36/0.30 | 0.90 | 3.80 | 1.15 | 6.40 | 14.60 | 7.41 | 30 |
| 4.00 | 56/0.30 | 1.00 | 4.50 | 1.15 | 7.40 | 16.80 | 4.95 | 34 |
| 6.00 | 84/0.30 | 1.00 | 5.25 | 1.15 | 8.00 | 18.70 | 3.30 | 43 |
| 10.00 | 140/0.30 | 1.00 | 6.50 | 1.40 | 9.90 | 23.70 | 1.91 | 61 |
| 16.00 | 224/0.30 | 1.00 | 8.00 | 1.40 | 11.80 | 28.00 | 1.21 | 81 |
| 25.00 | 350/0.30 | 1.20 | 10.10 | 2.00 | 14.70 | 35.50 | 0.780 | 108 |
| 35.00 | 490/0.30 | 1.20 | 11.30 | 2.00 | 16.80 | 39.50 | 0.554 | 135 |
| 50.00 | 703/0.30 | 1.40 | 13.30 | 2.20 | 18.30 | 45.50 | 0.386 | 170.00 |
| 70.00 | 988/0.30 | 1.40 | 15.30 | 2.20 | 20.00 | 51.00 | 0.272 | 220 |
| 95.00 | 1349/0.30 | 1.60 | 18.00 | 2.40 | 23.50 | 60.00 | 0.206 | 265 |
| 120.00 | 608/0.50 | 1.80 | 19.80 | 2.80 | 25.00 | 65.00 | 0.161 | 306 |
| 150.00 | 760/0.50 | 2.20 | 22.70 | 4.00 | 30.70 | 76.10 | 0.129 | 365 |
| Conductor | PVC Insulation | PVC Sheath | Conductor Resistance at 20°C (Max) |
Current Rating at 40°C Amps. |
||||
|---|---|---|---|---|---|---|---|---|
| Nominal Size in |
Nos. & Dia of Wire |
Nominal Thickness |
Nominal Core Dia |
Nominal Thickness |
Approx. Overall Dimensions |
|||
| Sq. mm. | Nos./mm | mm | mm | mm | Height mm | Width mm | ||
| 1.50 | 22/0.30 | 0.80 | 3.25 | 1.30 | 6.20 | 15.80 | 12.10 | 23 |
| 2.50 | 36/0.30 | 0.90 | 3.80 | 1.30 | 6.40 | 18.00 | 7.41 | 30 |
| 4.00 | 56/0.30 | 1.00 | 4.50 | 1.45 | 7.40 | 21.00 | 4.95 | 34 |
| 6.00 | 84/0.30 | 1.00 | 5.25 | 1.50 | 8.00 | 24.50 | 3.30 | 43 |
| 10.00 | 140/0.30 | 1.00 | 6.50 | 1.80 | 9.90 | 29.70 | 1.91 | 61 |
| 16.00 | 224/0.30 | 1.00 | 8.00 | 1.95 | 11.80 | 36.00 | 1.21 | 81 |
| 25.00 | 350/0.30 | 1.20 | 10.10 | 2.00 | 14.70 | 45.10 | 0.780 | 108 |
| 35.00 | 490/0.30 | 1.20 | 11.30 | 2.00 | 16.80 | 50.10 | 0.554 | 135 |
| 50.00 | 703/0.30 | 1.40 | 13.30 | 2.20 | 18.30 | 58.10 | 0.386 | 170 |
| 70.00 | 988/0.30 | 1.40 | 15.30 | 2.20 | 20.00 | 66.50 | 0.272 | 220 |
| 95.00 | 1349/0.30 | 1.60 | 18.00 | 2.40 | 23.50 | 77.30 | 0.206 | 265 |
| 120.00 | 608/0.50 | 1.80 | 19.80 | 3.50 | 27.40 | 87.00 | 0.161 | 306 |
The number of wires is approximate and wire diameter is nominal; they shall be such as to satisfy the requirements of conductor resistance of IEC 60228 / DIN VDE 0295 / IS 8130 / BS 6360
In view of continuous improvements in our design and process, specifications given here in are subject change without notice.