Designed for the secondary (high current) connection to automatic or hand - held metal arc battery electrodes. It is suitable for flexible use under rugged conditions, on assembly lines and conveyor operated line and spot battery machines
Current Rating :
The maximum current
ratings of flexible Battery cables are based on an ambient air
temperature of 25 C and a
o maximum conductor temperature of 90 C
Cross Sectional Area | Copper Construction | Inner Dia | Outer Dia Appx. | Max Conductor o Resistance at 20 C |
---|---|---|---|---|
Sq.mm | Nos.X Dia. mm | mm | mm | Ω/Km |
16 | 511 X 0.20 | 8.00 | 10.70 | 1.210 |
25 | 798 X 0.20 | 9.50 | 12.10 | 0.780 |
35 | 1121 X 0.20 | 11.00 | 14.20 | 0.554 |
50 | 1596 X 0.20 | 12.30 | 16.30 | 0.386 |
70 | 2220 X 0.20 | 14.40 | 18.70 | 0.272 |
95 | 1349 X 0.30 | 16.60 | 20.80 | 0.206 |
- The number of wires is approximate and wire diameter is nominal; they shall be such as to satisfy the requirements of conductor resistance of IEC 60228 / DIN VDE 0295 / IS 8130 / BS 6360
- In view of continuous improvements in our design and process, specifications given here in are subject change without notice
Ambient temperature °C | 20° | 25° | 30° | 35° | 40° | 45° | 50° | 55° | 60° | 65° |
Rating Factor | 1.04 | 1.00 | 0.96 | 0.91 | 0.87 | 0.82 | 0.76 | 0.69 | 0.64 | 0.57 |